Eutech CON 2700
Conductivity / Total Dissolved Solids / Salinity / Resistivity / Temperature
Featuring auto-standardization, auto-calibration and auto-ranging capabilities,
the Eutech CON 2700 accepts 2-cell and 4-cell electrodes, allowing a broad range
of measurement at up to ±1 % full scale accuracy. Meter comes with a multi
data screen that shows Conductivity readings, temperature, electrode status,
calibration points, date and time all at once.
• Chooseauto-calibrationwithpresetvaluesforquickeasycalibration,ormanual
multi-pointcalibrationforgreateraccuracy
• Easystandardizationwithauto-standardizationfeature–detecttheexactcell
constant value of your electrodes with the press of a button
• Quick,easyelectrodediagnosiswiththeeectivecellconstantsdisplay
• Replatinizationin5minuteswiththebuilt-inreplanitizationcircuit
• Non-volatilememoryholdsupto500datapoints–timeanddate-stampedfor
GLP compliance
• Bi-directionalRS232foreasydatatransfertocomputer
• Cal-duealarm–nomoreout-datedcalibrations!
• Auto-loggingfunctionforconvenientcontinuousmonitoring
• Limitalarmalertswhenreadingfallsoutofrange
• Passwordprotectionforsetupandcalibration
Applications: Environmental studies Chemical laboratories Quality assurance testing
• Food science • Ecological studies • Education institution
Eutech DO 2700
Dissolved Oxygen / BOD / Temperature
Designed for optimal performance and versatility, the DO 2700 come with
intuitive, advance set-up options for extensive user-customization at an
aordable price! Meter comes with self-stirring probe and bi-directional RS232
– ideal for BOD and other Dissolved Oxygen applications in the laboratory.
• MeasuresDissolvedOxygenin%saturation,ppm,mg/Lat
±0.5%fullscaleaccuracy
• Automaticcalibrationat100%andindependent0%–greatermeasurement
sensitivity during low oxygen levels
• AccuratereadingsinvaryingconditionswithTemperature,Salinityand
Barometric Pressure Compensation
• Non-volatilememoryholdsupto500datapoints–timeanddate-stampedfor
GLP compliance
• Bi-directionalRS232foreasydatatransfertocomputer
• Cal-duealarm–nomoreout-datedcalibrations!
• Auto-loggingfunctionforconvenientcontinuousmonitoring
• Limitalarmalertswhenreadingfallsoutofrange
• Passwordprotectionforsetupandcalibration
Applications: Environmental studies Wastewater and water treatment Ecological studies