Meters Specifi cations
page | 91
PCD 650 PC 650 PD 650 CD 650 PD 300 PC 300 PC 10
Multi-Parameter
Handheld Meters
Speci cations
Salinity
Range
.. to 0.770 ppm
0.770 ppm t
o 143.3 ppm
143.3 ppm t
o 2.138 ppt
2.138 ppt to 23.64 ppt
23.64 ppt to 80.00 ppt
.. to 0.770 ppm
0.770 ppm to 143.3 ppm
143.3 ppm to 2.138 ppt
2.138 ppt to 23.64 ppt
23.64 ppt to 80.00 ppt
Resolution 0.01 ppm / 0.1 ppm / 0.001 ppt / 0.01 ppt
0.01 ppm / 0.1 ppm /
0.001 ppt / 0.01 ppt
A
ccuracy ±1 % full scale + 1 LSD ±1 % full scale + 1 LSD
Resistivit
y
Range
2.000 Ω t
o 25.00 Ω
25.00 Ω to 250.0 Ω
250.0 Ω t
o 3.333 kΩ
3.333 kΩ to 500.0 kΩ
500.0 kΩ to 20.00 MΩ
2.000 Ω to 25.00 Ω
25.00 Ω to 250.0 Ω
250.0 Ω to 3.333 kΩ
3.333 kΩ to 500.0 kΩ
500.0 kΩ to 20.00 MΩ
Resolution 0.01 Ω / 0.1 Ω / 0.001 Ω / 0.1 Ω / 0.01 MΩ
0.01 Ω / 0.1 Ω / 0.001Ω /
0.1 Ω / 0.01 MΩ
A
ccuracy 1 % full scale 1 % full scale
Dissolved
Ox
y
gen
Range
0.00 to 90.00 mg/L
or ppm
0.00 t
o 90.00 mg/L or ppm
0.00 to 20.00 mg/L
or ppm
Resolution 0.01 mg/L ; 0.01 ppm 0.01 mg/L ; 0.01 ppm
A
ccuracy ±0.2 mg/L ±0.2 mg/L ±1.5 % full scale
Cal. Points 1– 1
Probe
Galvanic with integral
t
emperatur
e sensor
Galvanic with integral
temperature sensor
% Saturation
of Ox
y
gen
Range 0 to 600.0 % 0 to 600.0 % 0.0 to 200.0 %
Resolution 0.1 % 0.1 % 0.1 %
Accuracy ±2.0 % ±2.0 % ±1.5 % full scale
Salinity
C
orrection
Range 0.0 to 50.0 ppt 0.0 to 50.0 ppt 0.0 to 50.0 ppt
Resolution 0.1 ppt 0.1 ppt
Method Automatic / manual
A
ut
omatic
correction after
manual input
Automatic / manual
Automatic
correction after
manual input
Barometric
Pr
essure
Correction
Range
450 to 825 mmHg
or 59.9 t
o 109.9 kP
a
450 to 825 mmHg
or 59.9 to 109.9 kPa
500 to 1499 mmHg
or 66.6 to 199.9 kPa
Resolution 0.1 mmHg or 0.1 kPa 0.1 mmHg or 0.1 kPa
Method
Automatic
cor
r
ection with
built-in sensor
Automatic correction with built-in sensor
Automatic
correction after
manual input
Meter
Fe
atures
Temperature
Compensation
ATC / MTC (0 to 100 ºC)
GLP Yes
Cal-Due Alarm Yes
IP67 Yes
Datalogging Yes
Memory 500 data sets 50 data sets
Operating
T
emperatur
e
0 to 50 ºC
Ready Function Yes
Hold Function Yes
LCD Display
Dot-matrix LCD with backlight
(5.4 x 7.1 cm)
Dual-
displa
y LCD
with backlight
(5.8 x 3.3 cm)
Dual-display LCD
(5.8 x 3.3 cm)
Auto-Off 2 to 30 mins after last key pressed 20 mins after last key pressed
Input
DC phono sockets,
BNC, 8-pin
connec
t
or,
6-pin connector
DC phono sockets,
BNC,
8-pin connector
DC phono sockets,
BNC, 8-pin
connector
6-pin connector
DC phono sockets,
6-pin connector,
8-pin connector
BNC, 6-pin connector 6-pin connector
Output IrDA, RS232C (via LED) *
Power 4 x 1.5 V AA alkaline batteries or 9 V DC adapter, 500 mA 4 x 1.5 V AAA alkaline batteries
Battery Life > 200 hrs > 400 hrs > 200 hrs > 100 hrs > 50 hrs
Dimensions
(LxWxH)
; Weight
Meter 18.3 x 9.5 x 5.7 cm ; 460 g 19 x 10 x 6 cm ; 700 g
19 x 10 x 6 cm ; 320 g
Boxed 40 x 33 x 10 cm ; 3200 g 40 x 33 x 10 cm ; 2180 g
to
07
7
ppm
to
07
70
ppm
* RS232C (LED) interface adapter available as separate accessory (see page 92 for order information)
Vista de pagina 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 19 20

Comentarios a estos manuales

Sin comentarios