Instruction Manual
pH 11 & pH 110
Hand-held pH / mV / Temperature / RS 232 Meter
Technolo
g
y
M
ade
E
a
s
y
.
.
.
68X361301
Rev. 2 - 11/03
Vista de pagina 0
1 2 3 4 5 6 ... 75 76

Indice de contenidos

Pagina 1 - Instruction Manual

Instruction Manual pH 11 & pH 110 Hand-held pH / mV / Temperature / RS 232 Meter TechnologyMadeEasy...68X361301 Rev. 2 - 11/03

Pagina 2 - Rev. 2 - 11/03

Instruction Manual CyberScan pH 11 / 110 6 3.2 Connecting the pH Electrode Temperature Probe & Electrode Holder The pH 11/110 meter uses a

Pagina 3 - TABLE OF CONTENTS

Instruction Manual CyberScan pH 11 / 110 73.2.2 To connect the temperature probe: The temperature probe (provided) uses a 2.5 mm phono jack to

Pagina 4

Instruction Manual CyberScan pH 11 / 110 81. Align the flange of the second electrode holder with the slot of the first holder (Figure 8). 2.

Pagina 5 - 1 INTRODUCTION

Instruction Manual CyberScan pH 11 / 110 93.3 Connecting the AC/DC Adapter Besides using four AAA-sized batteries as a power source, the pH 11

Pagina 6 - 1.8.8.8

Instruction Manual CyberScan pH 11 / 110 103.4.1 RS232C Configuration The pH 110 meter has a 9 pin female RS232C connector with the following p

Pagina 7 - 2.2 Keypad

Instruction Manual CyberScan pH 11 / 110 114 CALIBRATION 4.1 Important Information on Meter Calibration When you re-calibrate your meter, pr

Pagina 8

Instruction Manual CyberScan pH 11 / 110 12 4.2.1 pH 11 meter calibration The pH 11 meter is capable of up to 5-point pH calibration to ensure

Pagina 9 - MADE IN S'PORE

Instruction Manual CyberScan pH 11 / 110 134.3 pH Calibration with ATC NOTE: We recommend that you perform at least 2-point calibration using

Pagina 10

Instruction Manual CyberScan pH 11 / 110 14 7. Rinse the probe with de-ionised water or a rinse solution, and place it in the next pH buffer.

Pagina 11

Instruction Manual CyberScan pH 11 / 110 154.4 mV Calibration (Offset) (Only for pH 110) With pH 110 meter, you can perform a calibration or a

Pagina 12

Preface This manual serves to explain the use of the hand-held series meters. The models covered are the pH 11 and the pH 110 hand-held meters. The m

Pagina 13 - Figure 10: Location of

Instruction Manual CyberScan pH 11 / 110 164.5 Temperature Calibration The temperature sensor is factory calibrated. Calibrate the temperature

Pagina 14

Instruction Manual CyberScan pH 11 / 110 175 MEASUREMENT This meter is capable of taking measurements with automatic or manual temperature comp

Pagina 15 - 4 CALIBRATION

Instruction Manual CyberScan pH 11 / 110 185.2 Manual Temperature Compensation IMPORTANT: For manual compensation, you must disconnect the tem

Pagina 16

Instruction Manual CyberScan pH 11 / 110 195.3 Taking Measurements Be sure to remove the electrode soaker bottle or protective rubber cap on th

Pagina 17 - 4.3 pH Calibration with ATC

Instruction Manual CyberScan pH 11 / 110 206 HOLD FUNCTION This feature lets you freeze the value of the pH, mV (or relative mV) and temperatur

Pagina 18 - Figure 12: Proceed to next

Instruction Manual CyberScan pH 11 / 110 217 MEMORY FUNCTION The memory function is available in both pH 11 and pH 110 meters. These meters sto

Pagina 19 - Figure 13: mV calibration

Instruction Manual CyberScan pH 11 / 110 227.2 Memory Recall This function recalls the previous readings stored in the memory. You can only ac

Pagina 20 - 4.5 Temperature Calibration

Instruction Manual CyberScan pH 11 / 110 238 PRINT FUNCTION (Only for pH 110) The pH 110 meter is equipped with an RS232 communication port an

Pagina 21 - 5 MEASUREMENT

Instruction Manual CyberScan pH 11 / 110 24• dAt / StO: Print Stored Data from Memory. This simply dumps all data stored in memory. You cannot

Pagina 22

Instruction Manual CyberScan pH 11 / 110 258.2.1 Print Current Data Manually To manually print any data that is currently being measured: 1.

Pagina 23 - 5.3 Taking Measurements

TABLE OF CONTENTS 1 INTRODUCTION...

Pagina 24 - 6 HOLD FUNCTION

Instruction Manual CyberScan pH 11 / 110 265 10secsecFrom measurement mode"MEM" annunicator will keep flashing during measurement mod

Pagina 25 - 7 MEMORY FUNCTION

Instruction Manual CyberScan pH 11 / 110 274. Press HOLD/ENTER key. The “Prn” primary display will flash until all data is printed. 5. To st

Pagina 26 - 7.2 Memory Recall

Instruction Manual CyberScan pH 11 / 110 28pHMEASREADY 23.47.03During measurement modeRepeat print procedure or press CAL to exit°CFor example,

Pagina 27

Instruction Manual CyberScan pH 11 / 110 299 ADVANCED SETUP FUNCTIONS The advanced setup mode lets you customised your meter’s preferences and

Pagina 28

Instruction Manual CyberScan pH 11 / 110 30From pH measurement mode From mV measurement modeSETUP SETUPMEM P 1.0 P 1.0SETUPpHCAL P 2.0SETUPELE

Pagina 29 - Flash for 0.5 seconds

Instruction Manual CyberScan pH 11 / 110 319.1 Advanced SETUP Mode Overview Press the SETUP key to enter Setup mode. Press the MI/▲ and MR/▼ k

Pagina 30 - From measurement mode

Instruction Manual CyberScan pH 11 / 110 32 9.1.2 mV Setup mode SETUP P 1.0COF P1.0: Unit Configuration P1.1 Ready indicator (On, Off or Auto

Pagina 31 - To stop, press PRINT key

Instruction Manual CyberScan pH 11 / 110 339.2 P1.0 : Unit Configuration This subgroup program allows customising the meter to your specific

Pagina 32 - Repeat print procedure or

Instruction Manual CyberScan pH 11 / 110 34 9.2.1 P1.1: READY Indicator and Auto Hold function Program P1.1 lets you select “READY indicator o

Pagina 33 - 9 ADVANCED SETUP FUNCTIONS

Instruction Manual CyberScan pH 11 / 110 359.2.2 P1.2: Select Calibration Buffer Options The types of pH calibration buffer options available

Pagina 34 - only in PH 110 but

9.3 P2.0: VIEWING PREVIOUS CALIBRATION DATA ... 38 9.4 P3.0: VIEW

Pagina 35 - P3.2 pH electrode slope

Instruction Manual CyberScan pH 11 / 110 369.2.3 P1.3 Select Number of pH Calibration Points Program P1.3 lets you select the number of calibr

Pagina 36

Instruction Manual CyberScan pH 11 / 110 379.2.4 P1.4 Select °C or °F Temperature Units Available in pH 110 meter only The pH 110 meter lets y

Pagina 37

Instruction Manual CyberScan pH 11 / 110 38 9.3 P2.0: Viewing Previous Calibration Data This mode lets you recall previous calibration data,

Pagina 38

Instruction Manual CyberScan pH 11 / 110 399.4 P3.0: View Electrode Data Program 3 has two “view only” options that let you check the electrod

Pagina 39

Instruction Manual CyberScan pH 11 / 110 409.4.2 View mV Offset (Only for pH 110) If you are in mV measurement mode, the display shows the rela

Pagina 40 - Figure 32: P1.3 - Select

Instruction Manual CyberScan pH 11 / 110 419.5 P4.0 : Auto-Off In Program P4.0 you can activate the AUTO-OFF option to automatically power off

Pagina 41 - Figure 33: P1.4 - Select

Instruction Manual CyberScan pH 11 / 110 429.6 P5.0 : Reset to Factory Default This mode lets you reset all parameters to factory default sett

Pagina 42 - Figure 34: P2.0 - View

Instruction Manual CyberScan pH 11 / 110 43 NOTE: Calibration reset is independent for each measurement parameter. That is: • From pH mode,

Pagina 43 - From pH measurement mode:

Instruction Manual CyberScan pH 11 / 110 449.7 P 6.0: Memory Clear (CLr) Use this parameter to clear all memory values when you need to store

Pagina 44 - Figure 36: P3.0 - View mV

Instruction Manual CyberScan pH 11 / 110 4510 CYBERCOMM PORTABLE DAS (Only for pH 110) The DAS software is designed for pH 110, CON 110 and DO

Pagina 45 - 9.5 P4.0 : Auto-Off

Instruction Manual CyberScan pH 11 / 110 11 INTRODUCTION Thank you for selecting the pH 11/110 meter. These meters are microprocessor-based ins

Pagina 46

Instruction Manual CyberScan pH 11 / 110 46 Figure 42: Click on 'Browse' button and locate CD-ROM drive Figure 43: Locate the Cybe

Pagina 47 - Figure 39: P5.2 - User reset

Instruction Manual CyberScan pH 11 / 110 47 Figure 44: Select ‘Portable Meters’ directory to go to CyberComm Portable. Figure 45: Open ‘Cybe

Pagina 48 - SETUP MEM

Instruction Manual CyberScan pH 11 / 110 48 Figure 46: Select "SETUP.EXE" program and click the OPEN button Figure 47: InstallShiel

Pagina 49 - 10.1 System Requirements

Instruction Manual CyberScan pH 11 / 110 49 Figure 49: Key in your name and company name and click NEXT button Figure 50: To select another

Pagina 50

Instruction Manual CyberScan pH 11 / 110 50 Figure 51: Creating a new program folder. Click on NEXT button. Figure 52: Click on NEXT button.

Pagina 51

Instruction Manual CyberScan pH 11 / 110 51 Figure 53: The CyberComm Portable DAS program is fully installed. Click on FINISH button to end ins

Pagina 52

Instruction Manual CyberScan pH 11 / 110 52 Figure 55: The opening screen will appear as above 10.3.1 Buttons & Check-Box • Enable Connect

Pagina 53

Instruction Manual CyberScan pH 11 / 110 53 Figure 56: Under File Menu setting, you can change various parameters. Under ABOUT menu, details of

Pagina 54

Instruction Manual CyberScan pH 11 / 110 54 Figure 57: Communication Settings for computer's Com port. It must match with COM port setting

Pagina 55

Instruction Manual CyberScan pH 11 / 110 5510.4 Capturing And Printing Data Into Computer Using Data Acquisition After matching the Communica

Pagina 56

Instruction Manual CyberScan pH 11 / 110 22 DISPLAY & KEYPAD FUNCTIONS 2.1 Display The LCD has a primary and secondary display. • The pri

Pagina 57

Instruction Manual CyberScan pH 11 / 110 5610.5 Trouble-shooting Guide a) Problem: Unable to PRINT When press PRINT key on pH 110 meter, nothi

Pagina 58

Instruction Manual CyberScan pH 11 / 110 5711 ELECTRODE CARE 11.1 Electrode Maintenance pH electrodes are susceptible to dirt and contamination

Pagina 59

Instruction Manual CyberScan pH 11 / 110 58rejuvenate it. (See section 11.4 on Rejuvenation Procedure). 11.2 Electrode Cleaning Electrodes that

Pagina 60 - 10.5 Trouble-shooting Guide

Instruction Manual CyberScan pH 11 / 110 5911.4 Rejuvenation Procedure 1. Dip and stir the electrode in freon or alcohol for 5 minutes. 2. Le

Pagina 61 - 11 ELECTRODE CARE

Instruction Manual CyberScan pH 11 / 110 6012 ERROR MESSAGES The following table provides a guideline to enable diagnosis of possible problems

Pagina 62 - 11.3 Electrode Activation

Instruction Manual CyberScan pH 11 / 110 6113 TROUBLE-SHOOTING PROBLEM PROBABLE CAUSE REMEDIAL ACTION Nothing is displayed when the ON/OFF key

Pagina 63 - 11.4 Rejuvenation Procedure

Instruction Manual CyberScan pH 11 / 110 6214 INFORMATION ON pH MEASUREMENT & ELECTRODE The previous sections of this manual describe the

Pagina 64 - 12 ERROR MESSAGES

Instruction Manual CyberScan pH 11 / 110 6314.1.3 pH and Temperature The electromotive force generated in the glass electrode varies with the

Pagina 65 - 13 TROUBLE-SHOOTING

Instruction Manual CyberScan pH 11 / 110 6414.3 Standard pH Buffers The following table shows the various pH values at different temperature o

Pagina 66 - 14.1 pH Measurements

Instruction Manual CyberScan pH 11 / 110 6515 LIST OF ACCESSORIES 15.1 Replacement Meter and Meter accessories Eutech Instruments Item Eutech

Pagina 67

Instruction Manual CyberScan pH 11 / 110 3 2.2 Keypad A large membrane keypad makes the instrument easy to use. Each button, when pressed, ha

Pagina 68 - 14.3 Standard pH Buffers

Instruction Manual CyberScan pH 11 / 110 6615.2 Oakton Instruments Item Oakton Instruments Order Code CyberScan pH 11 Portable pH/mV Meter with

Pagina 69 - Eutech Instruments

Instruction Manual CyberScan pH 11 / 110 6715.3 Calibration Solutions Item Eutech Instruments Order Code Oakton Instruments Order Code pH 4.01

Pagina 70 - 15.2 Oakton Instruments

Instruction Manual CyberScan pH 11 / 110 6816 FACTORY DEFAULT SETTINGS 16.1 pH 11 Factory Default Settings PROGRAM FUNCTION PARAMETER OPTIN

Pagina 71 - 15.3 Calibration Solutions

Instruction Manual CyberScan pH 11 / 110 6916.2 pH 110 Factory Default Settings PROGRAM FUNCTION PARAMETER OPTING KEYS PARAMETER OPTIONS DEFA

Pagina 72

Instruction Manual CyberScan pH 11 / 110 7017 SPECIFICATIONS MODEL NO. pH 11 pH 110 pH Range -2.00 to 16.00 pH -2.00 to 16.00 pH Resoluti

Pagina 73

Instruction Manual CyberScan pH 11 / 110 7118 WARRANTY This meter is supplied with a three-year warranty, six-month warranty for probe against

Pagina 74 - 17 SPECIFICATIONS

For more information on Eutech Instruments/ Oakton Instruments’ products, contact your nearest distributor or visit our website

Pagina 75 - 19 RETURN OF ITEMS

Instruction Manual CyberScan pH 11 / 110 4 MODEMEASCALENTERHOLDMRMISETUPOFFONMI MRSETUP MODEMEASCALENTERHOLDOFFONKeypad for pH 11 meter Keyp

Pagina 76

Instruction Manual CyberScan pH 11 / 110 53 PREPARATION 3.1 Inserting the Batteries This meter is packaged with 4 “AAA” alkaline batteries requ